Preperation Method
Preparation of hull cell panel surface prior to plating test
Panel Type
HULL M00 Polished + Plastic Tape / Film
HULL K00 Polished + Plastic Tape / Film
- Prepare all test equipment, cell, leads, chemistry, controller, etc.
- Remove plastic film and inspect panel surface.
- Use an approved acrylic adhesive remover,
ZEP Big Orange solution recommend by the tape manufacturer. - Anodic electro clean, Alkaline.
- Rinse with warm water.
- Activator. Acidic.
- Rinse with water
- Commence plating test within 30 seconds of activation.
Preferably 4 to 7 as per your own actual plating line setup.
NB: A slight colour difference may be present on the Cathodes after preparation is complete – This will not affect the Test Results of the Plating Solution.